from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class Gmonitoring:
"""Gmonitoring commands group definition. 2 total commands, 0 Sub-groups, 2 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._base = CommandsGroup("gmonitoring", core, parent)
[docs] def get_enable(self) -> bool:
"""SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:CPC:DDRX:GMONitoring:ENABle \n
Snippet: value: bool = driver.configure.cell.cpc.ddrx.gmonitoring.get_enable() \n
Defines the settings for the discontinuous reception in the downlink, see 'Continuous Packet Connectivity (CPC) '. \n
:return: enable: OFF | ON enables/disables UE monitoring of E-AGCH/E-RGCH when they overlap with the start of a UE DRX HS-SCCH reception
"""
response = self._core.io.query_str('CONFigure:WCDMa:SIGNaling<Instance>:CELL:CPC:DDRX:GMONitoring:ENABle?')
return Conversions.str_to_bool(response)
[docs] def set_enable(self, enable: bool) -> None:
"""SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:CPC:DDRX:GMONitoring:ENABle \n
Snippet: driver.configure.cell.cpc.ddrx.gmonitoring.set_enable(enable = False) \n
Defines the settings for the discontinuous reception in the downlink, see 'Continuous Packet Connectivity (CPC) '. \n
:param enable: OFF | ON enables/disables UE monitoring of E-AGCH/E-RGCH when they overlap with the start of a UE DRX HS-SCCH reception
"""
param = Conversions.bool_to_str(enable)
self._core.io.write(f'CONFigure:WCDMa:SIGNaling<Instance>:CELL:CPC:DDRX:GMONitoring:ENABle {param}')
[docs] def get_ithreshold(self) -> int:
"""SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:CPC:DDRX:GMONitoring:ITHReshold \n
Snippet: value: int = driver.configure.cell.cpc.ddrx.gmonitoring.get_ithreshold() \n
Number of subframes after uplink activity when UE has to monitor E-AGCH/E-RGCH, see 'Continuous Packet Connectivity (CPC)
'. \n
:return: threshold: Only the following values are allowed (in E-DCH TTIs) : 1 | 2 | 4 | 8 | 16 | 32 | 64 | 128 | 256 If you enter another value, the nearest allowed value is set instead. Range: 1 E-DCH TTI to 256 E-DCH TTI
"""
response = self._core.io.query_str('CONFigure:WCDMa:SIGNaling<Instance>:CELL:CPC:DDRX:GMONitoring:ITHReshold?')
return Conversions.str_to_int(response)
[docs] def set_ithreshold(self, threshold: int) -> None:
"""SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:CPC:DDRX:GMONitoring:ITHReshold \n
Snippet: driver.configure.cell.cpc.ddrx.gmonitoring.set_ithreshold(threshold = 1) \n
Number of subframes after uplink activity when UE has to monitor E-AGCH/E-RGCH, see 'Continuous Packet Connectivity (CPC)
'. \n
:param threshold: Only the following values are allowed (in E-DCH TTIs) : 1 | 2 | 4 | 8 | 16 | 32 | 64 | 128 | 256 If you enter another value, the nearest allowed value is set instead. Range: 1 E-DCH TTI to 256 E-DCH TTI
"""
param = Conversions.decimal_value_to_str(threshold)
self._core.io.write(f'CONFigure:WCDMa:SIGNaling<Instance>:CELL:CPC:DDRX:GMONitoring:ITHReshold {param}')