Harq¶
SCPI Commands
CONFigure:WCDMa:SIGNaling<Instance>:CELL:HSUPa:HARQ:POFFset
CONFigure:WCDMa:SIGNaling<Instance>:CELL:HSUPa:HARQ:RETX
- class Harq[source]
Harq commands group definition. 2 total commands, 0 Sub-groups, 2 group commands
- get_poffset() → float[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:POFFset value: float = driver.configure.cell.hsupa.harq.get_poffset()
Specifies the HARQ profile parameter ‘E-DCH MAC-d flow power offset’ signaled to the UE.
- return
power_offset: Range: 0 dB to 6 dB, Unit: dB
- get_re_tx() → int[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:RETX value: int = driver.configure.cell.hsupa.harq.get_re_tx()
Specifies the HARQ profile parameter ‘E-DCH MAC-d flow maximum number of retransmissions’ signaled to the UE.
- return
number: Range: 0 to 15
- set_poffset(power_offset: float) → None[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:POFFset driver.configure.cell.hsupa.harq.set_poffset(power_offset = 1.0)
Specifies the HARQ profile parameter ‘E-DCH MAC-d flow power offset’ signaled to the UE.
- param power_offset
Range: 0 dB to 6 dB, Unit: dB
- set_re_tx(number: int) → None[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:RETX driver.configure.cell.hsupa.harq.set_re_tx(number = 1)
Specifies the HARQ profile parameter ‘E-DCH MAC-d flow maximum number of retransmissions’ signaled to the UE.
- param number
Range: 0 to 15