Harq

SCPI Commands

CONFigure:WCDMa:SIGNaling<Instance>:CELL:HSUPa:HARQ:POFFset
CONFigure:WCDMa:SIGNaling<Instance>:CELL:HSUPa:HARQ:RETX
class Harq[source]

Harq commands group definition. 2 total commands, 0 Sub-groups, 2 group commands

get_poffset()float[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:POFFset
value: float = driver.configure.cell.hsupa.harq.get_poffset()

Specifies the HARQ profile parameter ‘E-DCH MAC-d flow power offset’ signaled to the UE.

return

power_offset: Range: 0 dB to 6 dB, Unit: dB

get_re_tx()int[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:RETX
value: int = driver.configure.cell.hsupa.harq.get_re_tx()

Specifies the HARQ profile parameter ‘E-DCH MAC-d flow maximum number of retransmissions’ signaled to the UE.

return

number: Range: 0 to 15

set_poffset(power_offset: float)None[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:POFFset
driver.configure.cell.hsupa.harq.set_poffset(power_offset = 1.0)

Specifies the HARQ profile parameter ‘E-DCH MAC-d flow power offset’ signaled to the UE.

param power_offset

Range: 0 dB to 6 dB, Unit: dB

set_re_tx(number: int)None[source]
# SCPI: CONFigure:WCDMa:SIGNaling<instance>:CELL:HSUPa:HARQ:RETX
driver.configure.cell.hsupa.harq.set_re_tx(number = 1)

Specifies the HARQ profile parameter ‘E-DCH MAC-d flow maximum number of retransmissions’ signaled to the UE.

param number

Range: 0 to 15